What energy efficiency class does your house have?
To estimate the energy efficiency class of your house, enter your annual consumption for heating and hot water and the living area. The tool estimates the class under annex 10 and shows how far you are from the next better one.
What is your home’s efficiency class?
Example: detached house from 1972, 140 m², certificate from March 2017, façade and windows planned. Change the answers to see your own result.
Efficiency class
E
| Energy value138 kWh/(m²·a) | |
| To the next better class8 kWh/m² less (D) | |
| Floor area used | 168 m² |
Estimate from your use, without weather adjustment: the certificate may differ slightly.
Sources
ss. 86, 82(2) GModG; annex 10
The efficiency class of a residential building follows from final energy per square metre of usable floor area per year. The bounds are in annex 10 of the Building Modernisation Act: A+ up to 30 kWh, A up to 50, and so on to H above 250 kWh. These bounds remain unchanged from 2027. In a consumption certificate, consumption is divided by the usable floor area; if only the living area is known, the law uses 1.2 times that area. Example: Our example house with 23,100 kWh a year and 140 m² of living area thus reaches 138 kWh/(m²·a), class E. The class is a mandatory detail in property adverts. It triggers no duty to renovate, but it affects the sale price and interest from tenants.
Site published by Radif Partners, independent: not an energy adviser, not an authority, no commission. · Editorial policy · Method and sources
Everything explained: Efficiency class ›
Energy efficiency class bounds for a house
The scale is in annex 10 GModG; section 86 requires residential buildings to be assigned a class on the certificate. What counts is the final energy value, the energy delivered to the house, not primary energy demand.
| Class | up to kWh/(m²·a) |
|---|---|
| A+ | 30 |
| A | 50 |
| B | 75 |
| C | 100 |
| D | 130 |
| E | 160 |
| F | 200 |
| G | 250 |
| H | over 250 |
How the class tool calculates
Your annual consumption is divided by the estimated usable floor area. Under section 82(2) GModG this is 1.2 times the living area, or 1.35 times for houses with up to 2 homes and a heated cellar. If hot water is produced locally, a flat rate is added: 20 kWh/(m²·a) until end-2026 and 16 from 2027 under the amending act.
In the example: 23,100 kWh divided by 168 m² gives 138 kWh/(m²·a), class E. Reaching class D takes 8 kWh less per square metre.
What a better class brings
One class up means lower heating bills and a better impression in adverts. The route almost always runs through the building envelope: insulating the façade, roof and basement ceiling, and new windows. BAFA pays a grant for these measures; what you are entitled to is worked out by the BAFA tool. How your use compares with the demand on the certificate is shown by the demand versus use comparison; which bills a consumption certificate needs, by the consumption certificate page.